Layer 3 Compact Access Switch for 10GE Uplink RG-S5350-48GT4XS-E
Full-gigabit access switch for large-sized enterprise and campus LANs, with four 10GE SFP+ ports for high-speed data transmission
Compare Products
Hide
VS
Characterized by security, high efficiency, intelligence, and energy saving, designed for network environments that require high performance, high port density, and easy installation
12 x 1GE RJ45 ports, 4 x 10GE SFP+ ports, PoE+
RG-S5350-24GT4XS-E24 x 1GE RJ45 ports, 4 x 10GE SFP+ ports
RG-S5350-24GT4XS-P-E24 x 1GE RJ45 ports, 4 x 10GE SFP+ ports, PoE+
RG-S5350-48GT4XS-E48 x 1GE RJ45 ports, 4 x 10GE SFP+ ports
RG-S5350-48GT4XS-P-E48 x 1GE RJ45 ports, 4 x 10GE SFP+ ports, PoE+
Full-gigabit access switch for large-sized enterprise and campus LANs, with four 10GE SFP+ ports for high-speed data transmission
Hardware Specifications
Port Specifications |
RG-S5350-24GT4XS-E |
RG-S5350-48GT4XS-E |
RG-S5350-12GT4XS-P-E |
RG-S5350-24GT4XS-P-E |
RG-S5350-48GT4XS-P-E |
Fixed service ports |
24 x 10/100/1000BASE-T ports 4 x 1GE/2.5GE/10GE SFP+ ports |
48 x 10/100/1000BASE-T ports 4 x 1GE/2.5GE/10GE SFP+ ports |
12 x 10/100/1000BASE-T ports, supporting PoE/PoE+ 4 x 1GE/2.5GE/10GE SFP+ ports |
24 x 10/100/1000BASE-T ports, supporting PoE/PoE+ 4 x 1GE/2.5GE/10GE SFP+ ports |
48 x 10/100/1000BASE-T ports, supporting PoE/PoE+ 4 x 1GE/2.5GE/10GE SFP+ ports |
Fixed management port |
1 x RJ45 console port |
||||
USB |
1 x USB 2.0 port (No capacity limit, 2G/4G/8G capacity tested) |
||||
USB hot swapping |
Supported |
||||
Cable hot swapping |
Supported by all ports |
System Specifications |
RG-S5350-24GT4XS-E |
RG-S5350-48GT4XS-E |
RG-S5350-12GT4XS-P-E |
RG-S5350-24GT4XS-P-E |
RG-S5350-48GT4XS-P-E |
System packet forwarding rate *1 |
96 Mpps |
132 Mpps |
78 Mpps |
96 Mpps |
132 Mpps |
System switching capacity *2 |
128 Gbps |
176 Gbps |
104 Gbps |
128 Gbps |
176 Gbps |
Switch buffer |
4 MB |
||||
CPU |
Dual-core CPU, each core with the clock speed of 1.0 GHz |
||||
Real-time clock (RTC) |
Supported |
||||
BootROM |
16 MB |
||||
Flash memory |
512 MB |
||||
Memory |
DDR4 1GB |
||||
Switch buffer |
4 MB |
||||
MAC address table size |
16,000 |
||||
ARP table size |
4,000 |
||||
Number of IPv4 unicast routes |
6,000 |
||||
Number of IPv4 multicast routes |
1,000 |
||||
Number of IPv6 unicast routes |
2,000 |
||||
Number of IPv6 multicast routes |
750 |
||||
Number of ACEs |
Ingress: 1,750 Egress: 800 |
||||
Number of VSU members |
4 |
*1 means the system's packet forwarding rate.
*2 means the system's switching capacity.
Dimensions and Weight |
RG-S5350-24GT4XS-E |
RG-S5350-48GT4XS-E |
RG-S5350-12GT4XS-P-E |
RG-S5350-24GT4XS-P-E |
RG-S5350-48GT4XS-P-E |
Unit dimensions (W x D x H) |
442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) |
||||
Shipping dimensions (W x D x H) |
540 mm x 338 mm x 154 mm (21.26 in. x 13.31 in. x 6.06 in.) |
||||
Rack height |
1 RU |
||||
Unit weight |
3.1 kg (6.83 lbs) |
3.25 kg (7.17 lbs) |
3.3 kg (7.28 lbs) |
3.4 kg (7.50 lbs) |
4.0 kg (8.82 lbs) |
Shipping weight |
4.10 kg (9.04 lbs) |
4.10 kg (9.04 lbs) |
4.18 kg (9.22 lbs) |
4.25 kg (9.37 lbs) |
4.90 kg (10.80 lbs) |
Mounting |
Mounting on a workbench/wall or in a rack (cabinet) |
Power supply and Consumption |
RG-S5350-24GT4XS-E |
RG-S5350-48GT4XS-E |
Power supply |
1 x fixed power supply |
|
Power input |
AC input ● Rated input voltage: 100 V AC to 240 V AC, 50 Hz to 60 Hz ● Maximum input voltage: 90 V AC to 264 V AC ● Maximum input current: 0.6 A |
AC input ● Rated input voltage: 100 V AC to 240 V AC, 50 Hz to 60 Hz ● Maximum input voltage: 90 V AC to 264 V AC ● Maximum input current: 1.5 A |
Maximum output power |
Built-in power supply: 25 W |
Built-in power supply: 40 W |
Maximum power consumption |
25 W |
40 W |
Leakage current |
≤ 3.5 mA |
|
Energy saving |
Supported |
Power supply and Consumption |
RG-S5350-12GT4XS-P-E |
RG-S5350-24GT4XS-P-E |
RG-S5350-48GT4XS-P-E |
Power supply |
1 x fixed power supply |
||
Power input |
AC input ● Rated input voltage: 100 V AC to 240 V AC, 50 Hz to 60 Hz ● Maximum input voltage: 90 V AC to 264 V AC ● Maximum input current: 6 A |
||
Maximum output power |
Built-in power supply: 409 W |
Built-in power supply: 460 W |
|
Maximum power consumption |
35 W (without PoE load) 405 W (full PoE load) |
52 W (without PoE load) 460 W (full PoE load) |
|
Leakage current |
≤ 3.5 mA |
||
PoE port |
All RJ45 ports support PoE/PoE+ (IEEE802.3af/at) power supply |
||
PoE power cable pairs |
Mode A (1-2, 3-6 pairs) |
||
PoE output power |
Each PoE port provides up to 30 W of power. The maximum power is 370 W. |
Each PoE port provides up to 30 W of power. The maximum power is 405 W. |
|
Energy saving |
supported |
Note: The maximum number of powered devices supported by the switch is determined by the available power of the switch and the actual power consumption of each device.
Environment and Reliability |
RG-S5350-24GT4XS-E |
RG-S5350-48GT4XS-E |
RG-S5350-12GT4XS-P-E |
RG-S5350-24GT4XS-P-E |
RG-S5350-48GT4XS-P-E |
Temperature |
Operating temperature: 0°C to 45°C (32°F to 113°F) Storage temperature: –40°C to +70°C (–40°F to +158°F) Note: At an altitude between 1,800 m (5,905.51 ft.) and 5,000 m (16,404.20 ft.), every time the altitude increases by 220 m (721.78 ft.), the maximum temperature decreases by 1°C (1.8°F). |
||||
Humidity |
Operating humidity: 10% to 90% RH (non-condensing) Storage humidity: 5% to 95% RH (non-condensing) |
||||
Altitude |
Operating altitude: 0 m to 5,000 m (0 ft. to 16,404.20 ft.) Storage altitude: 0 m to 5,000 m (0 ft. to 16,404.20 ft.) |
||||
Mean time between failure (MTBF |
207,962 hours (about 23 years) |
208,926 hours (about 23 years) |
211,466 hours (about 24 years) |
209,714 hours (about 23 years) |
200,253 hours (about 22 years) |
Fan |
No fan |
1 x fixed fan module |
|||
Heat dissipation |
Front-to-right and left-to-right airflow |
||||
Acoustic noise |
Fanless, quiet, < 20 dB |
27℃(80.6°F): 35 dB |
|||
Fan monitoring |
Fanless design |
PID-based multi-level speed adjustment Fan speed control (manual configuration not supported) Fan failure alarming |
|||
Temperature monitoring |
Supported |
||||
ESD |
ESD contact/air discharge: 6 kV/8 kV ESD susceptibility contact/air discharge: 8 kV/15 kV |
||||
Surge protection |
Power port: common mode 6 kV, differential mode 6 kV Communication port: 10 kV |
Software Specifications
Software Specifications |
RG-S5350-E Series |
Ethernet switching |
Jumbo frame (maximum length: 9,216 bytes) |
802.3az EEE |
|
IEEE 802.1Q (4K VLANs) |
|
Voice VLAN |
|
Super-VLAN and private VLAN |
|
MAC address-based VLAN, interface-based VLAN, protocol-based VLAN, and IP subnet-based VLAN |
|
GVRP |
|
Basic QinQ Selective QinQ |
|
STP, (IEEE 802.1.d), RSTP, (IEEE 802.1w), and MSTP (IEEE 802.1s) |
|
ERPS (G.8032) |
|
LLDP/LLDP-MED |
|
IP service |
Static and dynamic ARP, ARP proxy, and ARP entry timeout |
DHCP client, DHCP relay, and DHCP server |
|
DHCP snooping |
|
DNS |
|
DNS client, DNS proxy, and DNSv6 client |
|
DHCPv6 client, DHCPv6 relay, and DHCPv6 server |
|
DHCPv6 snooping |
|
Neighbor Discovery (ND) and ND snooping |
|
IP routing |
Static routing |
RIP and RIPng |
|
OSPFv2 and OSPFv3 |
|
IS-ISv4 and IS-ISv6 |
|
BGP4 and BGP4+ |
|
IPv4 and IPv6 VRF |
|
IPv4 and IPv6 PBR |
|
Multicast |
IGMP v1/v2/v3, and IGMP proxy |
IGMP v1/v2 snooping |
|
PIM-DM, PIM-SM, and PIM-SSM |
|
PIM SMv6, and PIM-SSMv6 |
|
MSDP |
|
MLDv1/v2 and MLD proxy |
|
MLD snooping v1/v2 |
|
PIM-SMv6 and PIM-SSM v6 |
|
Multicast source IP address check Multicast source port check |
|
Multicast querier |
|
ACL and QoS |
Standard IP ACLs Extended IP (hardware ACLs Extended MAC ACLs Time-based ACLs Expert-level ACLs ACL80 IPv6 ACLon IP addresses) |
Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers) |
|
Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type) |
|
Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range) |
|
Time based ACLS, ACL 80, and IPv6 ACL |
|
Global ACLs |
|
ACL redirection |
|
Traffic rate limiting on an interface |
|
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ |
|
Congestion avoidance: tail drop |
|
802.1p/DSCP/ToS traffic classification Eight priority queues per interface |
|
Security |
Multiple AAA modes |
RADIUS and TACAS+ |
|
RADIUS authentication and authorization |
|
IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication |
|
Web authentication |
|
HTTPS |
|
SSHv1 and SSHv2 |
|
Global IP-MAC binding |
|
ICMPv6 |
|
Port isolation and port security |
|
IP source guard |
|
SAVI |
|
ARP spoofing prevention |
|
CPP and NFPP |
|
Portal authentication and Portal 2.0 authentication |
|
ARP check DAI ARP packet rate limiting Gateway ARP spoofing prevention |
|
Broadcast storm suppression |
|
Hierarchical management of administrators and password protection |
|
BPDU guard |
|
Port protection |
|
Reliability |
REUP |
RLDP |
|
RLDP, Layer 2 link connectivity detection, and unidirectional link detection |
|
DLDP |
|
IPv4 VRRP v2/v3 and IPv6 VRRP |
|
BFD, NSR, VRRR, VRRP+ |
|
Basic LACP |
|
Link tracing, fault notification, and remote loopback based on 802.3ah (EFM) |
|
Dual-Boot Redundancy |
|
Fan speed adjustment Fan fault alarm |
|
Device virtualization |
Virtual Switching Unit (VSU) |
NMS and maintenance |
SPAN, RSPAN |
sFlow |
|
NTP and SNTP |
|
FTP and TFTP |
|
SNMP v1/v2c/v3 |
|
RMON (1, 2, 3, 9) |
|
NETCONF |
|
CWMP (TR-069) |
|
gRPC |
|
CLI (Telnet/Console) |
|
Web |
|
Syslog/Debug |
|
Various types of RMON groups, including event groups, alarm groups, history groups, and statistics groups, as well as private alarm extension groups |
|
RMON used to implement Ethernet statistics, historical statistics, and alarm functions |
|
OpenFlow Special 1.3 Flow table analysis defined by all protocols Transmission of specified packets to the controller Configuring the controller's IP address and port Notifying port status changes to the controller |
|
RNS, configuration rollback, and 802.3ah |
|
1:1 mirroring N:1 mirroring 1:N mirroring Flow-based local and remote mirroring |
|
PoE |
RG-S5350-12GT4XS-P-E, RG-S5350-E-24GT4XS-P-E, and RG-S5350-E-48GT4XS-P-E IEEE 802.3af and 802.3at Warm start Port priority Automatic and energy-saving power supply management modes Uninterrupted power supply in hot start mode Scheduled power-on or power-off of PoE ports based on the time policy |
Order switches, expansion modules, power supply modules, and other components as needed. Before ordering an expansion module or power supply module, please contact our online customer service team for the latest support information about the module.
Switches and Power Modules
Model |
Description |
RG-S5350-12GT4XS-P-E |
12 x 10/100/1000BASE-T ports, 4 x GE/2.5GE/10GE SFP+ ports, PoE power supply, support PoE+, a maximum of 370 W PoE output, and built-in power module |
RG-S5350-24GT4XS-E |
24 x 10/100/1000BASE-T ports, 4 x GE/2.5GE/10GE SFP+ ports, and built-in power module |
RG-S5350-48GT4XS-E |
48 x 10/100/1000 BASE-T, 4 x GE/2.5GE/10GE SFP+ ports, and built-in power module
|
RG-S5350-24GT4XS-P-E |
24 x 10/100/1000BASE-T ports, 4 x GE/2.5GE/10GE SFP+ ports, PoE power supply, support PoE+, a maximum of 370 W PoE output, and built-in power module |
RG-S5350-48GT4XS-P-E |
48 x 10/100/1000 BASE-T ports, 4 x GE/2.5GE/10GE SFP+ ports, PoE power supply, support PoE+, a maximum of 405 W PoE output, and built-in power module |
Note: 4 x 1GE/2.5G/10GE SFP+ ports support 1GE SFP transceivers, 2.5GE SFP transceivers and 10GE SFP+ transceivers.
Optical Transceivers and Cables
1GE
Model |
Description |
Mini-GBIC-GT |
1000BASE-X to 1000BASE-T, copper SFP transceiver, RJ45, 100 m over Cat 5e/6/6a The port needs to be configured with auto-negotiation |
MINI-GBIC-SX-MM850 |
1000BASE-SX, SFP transceiver, 850 nm, Duplex LC, 500 m over MMF |
MINI-GBIC-LX-SM1310 |
1000BASE-LX, SFP transceiver, 1310 nm, Duplex LC, 10 km over SMF |
MINI-GBIC-LH40-SM1310 |
1000BASE-LH, SFP transceiver, 1310 nm, Duplex LC, 40 km over SMF |
MINI-GBIC-ZX50-SM1550 |
1000BASE-ZX, SFP transceiver, 1550 nm, Duplex LC, 50 km over SMF |
MINI-GBIC-ZX80-SM1550 |
1000BASE-ZX, SFP transceiver, 1550 nm, Duplex LC, 80 km over SMF |
MINI-GBIC-ZX100-SM1550 |
1000BASE-ZX, SFP transceiver, 1550 nm, Duplex LC, 100 km over SMF |
GE-SFP-LX03-SM1310-BIDI-I |
1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 3 km over SMF |
GE-SFP-LX03-SM1550-BIDI-I |
1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 3 km over SMF |
GE-SFP-LX20-SM1310-BIDI |
1000BASE-LX, SFP transceiver, Tx1310/Rx1550, BiDi LC, 20 km over SMF |
GE-SFP-LX20-SM1550-BIDI |
1000BASE-LX, SFP transceiver, Tx1550/Rx1310, BiDi LC, 20 km over SMF |
GE-SFP-LH40-SM1310-BIDI |
1000BASE-LH, SFP transceiver, Tx1310/Rx1550, BiDi LC, 40 km over SMF |
GE-SFP-LH40-SM1550-BIDI |
1000BASE-LH, SFP transceiver, Tx1550/Rx1310, BiDi LC, 40 km over SMF |
Note: BiDi transceivers must be used in pairs. If one end uses GE-SFP-LX20-SM1310-BIDI, the other end must use GE-SFP-LX20-SM1550-BIDI.
2.5GE
Model |
Description |
2.5G-SFP-LX03-SM1310-BIDI-I |
2.5GBASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 3 km over SMF |
2.5G-SFP-LX03-SM1550-BIDI-I |
2.5GBASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 3 km over SMF |
10GE
Model |
Description |
XG-SFP-SR-MM850 |
10GBASE-SR, SFP+ transceiver, 850nm, Duplex LC, 300 m over MMF |
XG-SFP-LR-SM1310 |
10GBASE-LR, SFP+ transceiver, 1310nm, Duplex LC, 10 km over SMF |
XG-SFP-ER-SM1550 |
10GBASE-ER, SFP+ transceiver, 1550nm, Duplex LC, 40 km over SMF |
XG-SFP-ZR-SM1550 |
10GBASE-ZR, SFP+ transceiver, 1550nm, Duplex LC, 80 km over SMF |
XG-SFP-LR10-SM1270-BIDI-I |
10GBASE-LR, SFP+ transceiver, TX1270/RX1330, BiDi LC, 10 km over SMF |
XG-SFP-LR10-SM1330-BIDI-I |
10GBASE-LR, SFP+ transceiver, TX1330/RX1270, BiDi LC, 10 km over SMF |
XG-SFP-AOC1M |
10GBASE, SFP+ active optical cable (AOC), 1 m, including one cable and two optical transceivers |
XG-SFP-AOC3M |
10GBASE, SFP+ active optical cable (AOC), 3 m, including one cable and two optical transceivers |
XG-SFP-AOC5M |
10GBASE, SFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Contact Us
How can we help you?
Your opinions and feelings are crucial for our improvement.
Fill in the survey